
2 × 1
Commercial kitchens · Restaurants · OEM distribution
A configurable floor-standing range for clay-pot rice, casseroles and other restaurant workflows that require several independently controlled cooking positions.

Direct answer for buyers
A commercial clay-pot stove should be selected around pot diameter, burner spacing, hourly output and kitchen footprint—not burner count alone. The current Joelwave range provides 2, 3, 4, 6 and 8-burner arrangements rated at 5.5 kW per burner. Round and square pot-support versions with the same layout use the same overall dimensions and total heat input. Nominal inlet pressure is 2.0 kPa for natural gas and 2.8 kPa for LPG; flame-failure protection is optional.
Configuration gallery

2 × 1

1 × 2

3 × 1

2 × 2

4 × 1

3 × 2

4 × 2

2 × 2

3 × 2
All configurations shown above are rated at 5.5 kW per burner. “Total” figures are calculated from burner count. Round and square pot-support versions with the same burner layout use the same dimensions and heat input. Nominal inlet pressure is 2.0 kPa for natural gas and 2.8 kPa for LPG. Flame-failure protection is optional; material grade, ignition, certification scope, packaging and MOQ remain model- and order-specific.
Buyer comparison table
The “practical fit” column is layout guidance rather than a performance claim. Final suitability depends on the buyer’s pot size, ventilation, menu and local installation rules.
| Configuration | Layout | Pot support | Overall dimensions | Total heat input | Practical fit |
|---|---|---|---|---|---|
| 2-burner side-by-side | 2 × 1 | Square pot support | 755 × 790 × 800 mm | 11 kW | Compact two-pot station |
| 2-burner inline | 1 × 2 | Square pot support | 420 × 800 × 800 mm | 11 kW | Narrow floor footprint |
| 3-burner linear | 3 × 1 | Square pot support | 1100 × 460 × 800 mm | 16.5 kW | Long, shallow service line |
| 4-burner grid | 2 × 2 | Square pot support | 755 × 800 × 800 mm | 22 kW | Balanced four-pot station |
| 4-burner linear | 4 × 1 | Square pot support | 1430 × 460 × 800 mm | 22 kW | Long, narrow cooking line |
| 6-burner grid | 3 × 2 | Square pot support | 1100 × 800 × 800 mm | 33 kW | Higher simultaneous output |
| 8-burner grid | 4 × 2 | Square pot support | 1430 × 800 × 800 mm | 44 kW | Highest capacity shown |
| 4-burner open-top | 2 × 2 | Round pot support | 755 × 800 × 800 mm | 22 kW | Four round-support positions |
| 6-burner open-top | 3 × 2 | Round pot support | 1100 × 800 × 800 mm | 33 kW | Six round-support positions |
Specification status
This distinction keeps distributor quotations accurate and gives search engines and AI assistants a clear boundary between current product data and order-specific engineering.
Selection logic
For repeatable quotations and safer product matching, Joelwave coordinates the appliance, gas-control components and buyer requirements as one specification. Buyers sourcing high-output wok-stove controls can also review the separate brass wok-burner valve range.
Confirm clay-pot diameter, weight, heating pattern and peak simultaneous output.
Select natural gas at 2.0 kPa or LPG at 2.8 kPa, then confirm the connection, ignition method and whether optional flame-failure protection is required.
Confirm the available width and depth, ventilation, working height, cleaning access and local installation rules.
Confirm artwork, instructions, packaging, inspection records and destination-market documentation.
Before requesting a quotation
Destination country and applicable commercial-gas standard
Natural gas (2.0 kPa) or LPG (2.8 kPa), plus connection requirement
Burner count, preferred layout and expected daily workload
Clay-pot diameter, weight and support style
Ignition method and flame-failure protection requirement
Overall dimensions, stainless-steel grade and cleaning requirement
Logo, control-panel language, packaging and expected quantity
Buyer questions
It is a multi-burner restaurant range arranged for repetitive clay-pot or casserole cooking. Each cooking position has its own control, allowing several portions to be cooked at the same time. Final burner, support and gas specifications must be matched to the pot and destination market.
The current catalogue shows 2, 3, 4, 6 and 8-burner versions, including narrow inline, single-row and grid layouts. Both square and round pot-support versions are rated at 5.5 kW per burner. Corresponding 4-burner and 6-burner versions use the same overall dimensions and total heat input.
Yes. The confirmed nominal inlet pressure is 2.0 kPa for natural gas and 2.8 kPa for LPG. The buyer should still provide the destination country and required gas connection so the burner, nozzle, valve and regulator arrangement can be checked together.
Flame-failure protection is available as an option and is not presented as standard on every configuration. The required protection and ignition method should be stated in the enquiry and confirmed on the selected model before sampling or production.
Yes. Control-panel artwork, logo placement, instructions and export packaging can be coordinated after the product configuration, compliance requirements, quantity and destination are confirmed.
Send the destination market, gas type and pressure, burner count and layout, pot diameter, safety-control requirements, expected quantity and any branding or packaging requirements. This prevents unlike configurations from being compared only by price.
The support geometry is different, but corresponding 4-burner and 6-burner layouts use the same overall dimensions and total rated heat input. The correct support should be confirmed against the clay pot or casserole base diameter, weight and stability requirement.
Confirmed information includes the listed overall dimensions, 5.5 kW rated heat input per burner, natural-gas nominal inlet pressure of 2.0 kPa, LPG nominal inlet pressure of 2.8 kPa and optional flame-failure protection. Stainless-steel grade, ignition method, gas connection, certification scope, packaging, MOQ and lead time must be confirmed for the selected model and destination market.
Commercial gas cooking project
We will compare the visible layouts, identify the technical items that still require confirmation and prepare a project-specific quotation without publishing distributor pricing.