Original configuration
Vertical pilot-tube connection
The tube exits upward and can contact the top cover. Bending it to make space can introduce a vulnerable point.

Original design reference · Not the SA-032AG supplied configuration
Featured component / SA-032AG
SA-032AG combines piezoelectric ceramic ignition with a 45° upward-angled pilot-tube connection. Designed to clear the stove top cover without bending the pilot tube to avoid contact, for medium-pressure wok-stove projects in Southeast Asia and the Middle East.

Inlet pressure range
Product weight
Ceramic ignition
Purpose-built component
SA-032AG combines gas control with piezoelectric ceramic ignition for medium-pressure wok-stove applications. The photographed assembly shows the valve, copper tube, ignition lead and electrode bracket together.
For a new stove design or a replacement-parts programme, start with the operating pressure and installation interfaces. We will confirm the supplied configuration against your requirements.
Review the specifications ↓The design improvement
The pilot-tube connection is angled upward at 45° to provide clearance beneath the stove top cover. In the intended installation, the tube does not need to be bent to avoid the cover, reducing the risk of damage and breakage caused by interference.
Original configuration
The tube exits upward and can contact the top cover. Bending it to make space can introduce a vulnerable point.

Original design reference · Not the SA-032AG supplied configuration
Optimized SA-032AG
The pilot tube follows a sloping route away from the cover. No cover-clearance bend is needed in the intended stove layout.

SA-032AG · Angled outlet and straight pilot tube
Connection angle describes the design in its installed orientation. Confirm final cover clearance, mounting and tube routing against your stove drawing or sample.
Integrated automated production
Our manufacturing partner uses a fully automated production line integrating machining, assembly and testing. The process supports reliable production capacity while improving consistency from one valve to the next.
Automated machining of the aluminum casting.
Automated assembly within the integrated production line.
Automated leakage testing within the production process.
Automated durability testing as part of the integrated testing workflow.
Test conditions, cycle counts and acceptance criteria are confirmed for your order.

From component to stove
The installation photo shows the valve within a wok-stove assembly, alongside the gas connection and ignition routing.
SA-032AG is intended for medium-pressure wok stoves used in Southeast Asia, the Middle East and similar application markets. Match the valve connections, mounting position and electrode arrangement to the specific stove.
Send your stove photos ↗Technical overview
Confirm gas type, connection dimensions, mounting and supplied accessories with your sample or drawing.
| Model | SA-032AG |
|---|---|
| Product type | Piezoelectric ceramic ignition gas valve |
| Application | Medium-pressure, high-output wok stove |
| Inlet pressure range | 100–250 kPa (0.10–0.25 MPa / 1–2.5 bar) |
| Weight | 230 g |
| Pilot-tube connection | 45° upward-angled |
| Valve body | Aluminum casting |
| Manufacturing | Fully automated machining, assembly, leakage testing and life-cycle testing |
| Primary application markets | Southeast Asia · Middle East |
Product photography
Open a photograph to inspect the connections, shaft, bracket and ignition components.
Before requesting a sample
Gas type and actual operating inlet pressure.
Inlet/outlet sizes and tubing arrangement.
Mounting dimensions, shaft and electrode position.
Destination market, sample quantity and production volume.
Buyer questions
The original upward-facing pilot-tube connection can place the tube in the path of the stove top cover, requiring a bend and creating a risk of damage or breakage. SA-032AG uses a 45° upward-angled connection so the tube can clear the cover without that bend in the intended installation. Confirm clearance against your stove layout.
Our manufacturing partner uses an integrated, fully automated production line covering turning and milling of aluminum castings, assembly, leakage testing and life-cycle testing. This supports production capacity and more consistent product quality. Test conditions and acceptance criteria are confirmed for the order.
SA-032AG is designed for medium-pressure, high-output wok stoves, with primary applications in Southeast Asia and the Middle East.
The specified inlet pressure range is 100–250 kPa, equivalent to 0.10–0.25 MPa or 1–2.5 bar. Product weight is 230 g.
Send your gas type, operating inlet pressure, burner photos or drawing, connection sizes, mounting details and required quantity. We will review the valve and ignition assembly against your stove.
Contact us with your application and sample quantity. Sample availability, supplied accessories, lead time and shipping are confirmed in the quotation.
SA-032AG · OEM / wholesale inquiries
Send your market, quantity and stove photos. We will confirm the configuration, sample plan, lead time and project quotation.