Featured component / SA-032AG

45° pilot connection.
Room for the tube.

SA-032AG combines piezoelectric ceramic ignition with a 45° upward-angled pilot-tube connection. Designed to clear the stove top cover without bending the pilot tube to avoid contact, for medium-pressure wok-stove projects in Southeast Asia and the Middle East.

SA-032AG complete piezo ignition valve assembly with copper tube, ignition lead and ceramic electrode
SA-032AG · Valve and ignition assembly
100–250 kPa

Inlet pressure range

230 g

Product weight

Piezo

Ceramic ignition

One valve platform.
A clear application.

SA-032AG combines gas control with piezoelectric ceramic ignition for medium-pressure wok-stove applications. The photographed assembly shows the valve, copper tube, ignition lead and electrode bracket together.

For a new stove design or a replacement-parts programme, start with the operating pressure and installation interfaces. We will confirm the supplied configuration against your requirements.

Review the specifications ↓

A better angle.
Less interference under the cover.

The pilot-tube connection is angled upward at 45° to provide clearance beneath the stove top cover. In the intended installation, the tube does not need to be bent to avoid the cover, reducing the risk of damage and breakage caused by interference.

Vertical pilot-tube connection

The tube exits upward and can contact the top cover. Bending it to make space can introduce a vulnerable point.

Original valve reference with upward-facing pilot-tube connection and bent copper pilot tube

Original design reference · Not the SA-032AG supplied configuration

45° upward-angled connection

The pilot tube follows a sloping route away from the cover. No cover-clearance bend is needed in the intended stove layout.

Optimized SA-032AG showing the angled pilot-tube outlet and straight copper tube routing

SA-032AG · Angled outlet and straight pilot tube

Connection angle describes the design in its installed orientation. Confirm final cover clearance, mounting and tube routing against your stove drawing or sample.

From aluminum casting
to assembled, tested valve.

Our manufacturing partner uses a fully automated production line integrating machining, assembly and testing. The process supports reliable production capacity while improving consistency from one valve to the next.

  1. 01

    Turning & milling

    Automated machining of the aluminum casting.

  2. 02

    Assembly

    Automated assembly within the integrated production line.

  3. 03

    Leakage testing

    Automated leakage testing within the production process.

  4. 04

    Life-cycle testing

    Automated durability testing as part of the integrated testing workflow.

Test conditions, cycle counts and acceptance criteria are confirmed for your order.

Actual wok-stove installation showing the valve mounted beneath the stove and connected to the burner assembly
Actual application · Underside of a wok-stove assembly

From component to stove

See where it fits.

The installation photo shows the valve within a wok-stove assembly, alongside the gas connection and ignition routing.

SA-032AG is intended for medium-pressure wok stoves used in Southeast Asia, the Middle East and similar application markets. Match the valve connections, mounting position and electrode arrangement to the specific stove.

Send your stove photos ↗

SA-032AG specifications.

Confirm gas type, connection dimensions, mounting and supplied accessories with your sample or drawing.

Product specifications
ModelSA-032AG
Product typePiezoelectric ceramic ignition gas valve
ApplicationMedium-pressure, high-output wok stove
Inlet pressure range100–250 kPa (0.10–0.25 MPa / 1–2.5 bar)
Weight230 g
Pilot-tube connection45° upward-angled
Valve bodyAluminum casting
ManufacturingFully automated machining, assembly, leakage testing and life-cycle testing
Primary application marketsSoutheast Asia · Middle East

Four details help us match your stove.

01

Gas & pressure

Gas type and actual operating inlet pressure.

02

Connections

Inlet/outlet sizes and tubing arrangement.

03

Installation

Mounting dimensions, shaft and electrode position.

04

Order scope

Destination market, sample quantity and production volume.

Planning your SA-032AG order.

What is improved compared with the original valve design?

The original upward-facing pilot-tube connection can place the tube in the path of the stove top cover, requiring a bend and creating a risk of damage or breakage. SA-032AG uses a 45° upward-angled connection so the tube can clear the cover without that bend in the intended installation. Confirm clearance against your stove layout.

How is SA-032AG manufactured?

Our manufacturing partner uses an integrated, fully automated production line covering turning and milling of aluminum castings, assembly, leakage testing and life-cycle testing. This supports production capacity and more consistent product quality. Test conditions and acceptance criteria are confirmed for the order.

What type of stove is SA-032AG designed for?

SA-032AG is designed for medium-pressure, high-output wok stoves, with primary applications in Southeast Asia and the Middle East.

What are the inlet pressure range and weight?

The specified inlet pressure range is 100–250 kPa, equivalent to 0.10–0.25 MPa or 1–2.5 bar. Product weight is 230 g.

What should I send to confirm compatibility?

Send your gas type, operating inlet pressure, burner photos or drawing, connection sizes, mounting details and required quantity. We will review the valve and ignition assembly against your stove.

Can I request a sample before a production order?

Contact us with your application and sample quantity. Sample availability, supplied accessories, lead time and shipping are confirmed in the quotation.

Bring us your next wok-stove project.

Send your market, quantity and stove photos. We will confirm the configuration, sample plan, lead time and project quotation.